2020-3-12 · DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DATA SHEET E 025 N 023 ANE N 023.1.2 AN.30E, very quiet version Concept The diaphragm vacuum pumps from KNF are based on a simple principle – an elastic diaphragm, fixed on its edge, moves up and down its central point by means of an eccentric. In this way the medium is transferred using automatic …
2021-12-10 · BECKER U 5.201• 3 Current consumption and rotation speed may vary. Tolerance in each case -1.5/+2% 3~ Motors L # 50 Hz 60 Hz Version Weight kW V min-1 A kW V min-1 A kg mm [inch] 01 4.0 Δ230/Y400 IE3 1465 15.6/9.0 4.8 Δ265/Y460 Δ230/Y400 IE3
2021-1-19 · Product Data Sheet EasternPlastics IGast IInnovadyne IIsmatec IIsolationTechnologies IJun-Air Micropump IRheodyne ISapphireEngineering ISemrock ISystec ITrebor IUpchurchScientific The Systec ZHCR (Zero Hysteresis / Constant Run) vacuum pump is designed for merane degassing of the HPLC mobile
2017-10-24 · Datasheet T V Mleaa apelle aa e el Te [email protected] Oil-free vacuum pump. The absence of lubricant and oil in the piston makes it maintenance free. This vacuum pump can be used with for instance the AB3655, Automatic Film Applior Compact. • Oil-free, maintenance free • Overflow protection • Moisture trap with filter cartridge
2010-5-5 · Product Data Sheet Mobil Vacuum Pump Oil Product Description Mobil Vacuum Pump Oil is a high Viscosity Index, medium viscosity straight mineral oil made from very high quality solvent refined base oils for the lubriion of vacuum pump cylinders. Precautions are taken to ensure that Mobil Vacuum Pump Oil is free from water prior to packaging
STP-iX455 Turbomolecular vacuum pump datasheet 3 Pages. Add to favorites {{requestButtons}} alog excerpts. This pump features 450 l/s pumping speed for nitrogen. The STP-iX455 is an excellent fit for electron microscopy, metrology, lithography and other vibration-sensitive appliions. > Compact Design Including a Fully Integrated
2017-4-16 · MINI DIAPHRAGM VACUUM PUMPS AND COMPRESSORS N 85.3 KNE N 86 KNDC N 86 KNDCB DATA SHEET E008 Type Delivery Vacuum atm. Pressure Weight (l/min) (ar abs) Press. (bar g) (kg) N 85.3 KNE 5 25 0.3 1.25 …
2021-9-16 · DATA SHEET BCV 100 CLAW VACUUM PUMPS dry and contact free compression air-cooled. 2 • BECKER BCV 100 58.8 70.6 37.5 28.1 67 (450 Torr) 71 (450 Torr) 211.7 21.2 21 1718.7.7 11.8 17.3
2020-6-3 · Technical data sheet The Vacuum Pump V-100 is an economical and chemically resistant PTFE diaphragm vacuum pump with a space saving design. It covers the essential needs in vacuum generation. On/off-regulated by the Interface I-100, it is optimally suited to work with the Rotavapor® R-100. The ready to use vacuum pump will be delivered with a
2018-10-22 · Trade name : FJC VACUUM PUMP OIL. CAS No : 64742-52-5 Product code : 2200, 2200-55, 2202 1.2. Relevant identified uses of the substance or mixture and uses advised against Use of the substance/mixture : Vacuum Pump Oil 1.3. Details of the supplier of the safety data sheet Supplier Address FJC 101 Commercial Drive Mooresville, NC 28115 1.4.
2022-1-6 · DATA SHEET VT 4.8 ROTARY VANE VACUUM PUMPS oil-free air-cooled. 2 • BECKER VT 4.8 a b d e 3.2 f 0.3 m p o h g n i. 1 r G3/8 k c V3 V1 P3 V4 P4 V3 P3 V1 1~ * V2 V1 (V2) V3 (V4) P3 (P4) (XX) * Vacuum connection (G⅜) Vacuum regulating valve Blow-off valve Alternative The size and position of the capacitor can change with changed voltage
• VARIAIR SV 400/1 Vacuum Pump Data Sheet • VT 4.4 Data Sheet • VT 4.8 Data Sheet • VT 4.10 Data Sheet • VT 4.16 Data Sheet • VT 4.25 Data Sheet • VT 4.40 Data Sheet • VTLF 2.200 Data Sheet • VTLF 2.250 NEMA Data Sheet • VTLF 2.250 SK NEMA Data Sheet
EM18 VACUUM PUMPS - PRODUCT SERVICE RECOMMENDATIONS Performance optimisation through regular maintenance. As with all mechanical devices, regular maintenance can help ensure optimised, safe performance of your Edwards EM Series vacuum pump.Please refer to the maintenance schedule for recommended maintenance Edwards offers oils, service …
DATA SHEET ROTARY VANE VACUUM PUMPS oil-free air-cooled. 2 • BECKER VT 4.25 1) 2) According to DIN EN ISO 3744 (KpA = 3 dB(A)), 1 m [39.4 inch] distance, at medium load, both connection sides piped Depending on the motor See separate data sheet Possible coinations on request
DATA SHEET VT 4.8 ROTARY VANE VACUUM PUMPS oil-free air-cooled. 2 • BECKER VT 4.8 a b d e 3.2 f 0.3 m p o h g n i. 1 r G3/8 k c V3 V1 P3 V4 P4 V3 P3 V1 1~ * V2 V1 (V2) V3 (V4) P3 (P4) (XX) * Vacuum connection (G⅜) Vacuum regulating valve Blow-off valve Alternative The size and position of the capacitor can change with changed voltage
Liquid Ring Vacuum Pump Data Sheet - Graham Corporation | Graham Corporation. Graham is pleased to provide a couple of resources to assist in identifying your project needs. Once the completed data sheet is submitted to our office, our team will be in contact with you to advise how Graham can best suit your needs.
2021-1-19 · Product Data Sheet EasternPlastics IGast IInnovadyne IIsmatec IIsolationTechnologies IJun-Air Micropump IRheodyne ISapphireEngineering ISemrock ISystec ITrebor IUpchurchScientific The Systec ZHCR (Zero Hysteresis / Constant Run) vacuum pump is designed for merane degassing of the HPLC mobile
2014-10-11 · Vacuum Pump Datasheet:,,,Pump,,PUMP,pump,pump,pump,pump
2017-10-3 · vacuum pump (G1) , all regulating devices to control flow of water and pump motor shut off electrical components. The vacuum pump power requirement is specified at 220/240VAC, 50/60Hz, 1.5 HP, 1 phase. The vacuum pump is able to establish the total required vacuum pressure in less than 30 minutes for system capacity up to 4000 gallons.
2021-8-25 · Technical data sheet The Vacuum Pump V-100 is an economical and chemically resistant PTFE diaphragm vacuum pump with a space saving design. It covers the essential needs in vacuum generation. On/off-regulated by the Interface I-100, it is optimally suited to work with the Rotavapor® R-100. The ready to use vacuum pump will be delivered with a
2021-7-8 · DATA SHEET E 296 Flow rate [m³/h] at atm. pressure 1.26 Flow rate [l/min] at atm. pressure 21 Ultimate vacuum [ar abs.] 2.0 < 5.0 with gas ballast valve in use Nominal voltage [V] 100 – 240 Frequency [Hz] 50 – 60 Power P 1 [W] max. 135 Operating current [A] max. 1.7 With overcurrent protection and main fuse MATERIALS Pump head PPS
EM18 VACUUM PUMPS - PRODUCT SERVICE RECOMMENDATIONS Performance optimisation through regular maintenance. As with all mechanical devices, regular maintenance can help ensure optimised, safe performance of your Edwards EM Series vacuum pump.Please refer to the maintenance schedule for recommended maintenance Edwards offers oils, service …
2021-9-24 · Technical Datasheet Medical Vacuum Plant HTM 02-01 • 450 mmHg • 60 Hz Description Medical Vacuum Plants are intended to provide a continuous supply of medical vacuum to a pipeline system in healthcare facilities. The system shall be ‘duplexed’ such that the supply is maintained in single fault condition. Two standby pumps
Agilent Varian IDP-15 Oil-Free Dry Scroll Vacuum Pump Data Sheet.pdf (0) Turbo Pumps: Agilent Varian 74 FS Rack Mount Turbo Pump Controller Instruction Manual.pdf (7.73 ) Agilent Varian 74 FS Turbomolecular Vacuum Pump Data Sheet.pdf (0.68 ) Agilent Varian TwisTorr 305 FS Onboard Controller User Manual.pdf (1.65 )
2020-6-3 · Vacuum Pump V-700 / V-710 Technical data sheet The Vacuum Pump V-700 and V-710 is a chemically resistant PTFE diaphragm pump, de-signed for use with all gases and vapors typically associated with the lab. The pump is opti-mally suited for work with laboratory and industrial rotary evaporators as well as other typical
2020-6-3 · Vacuum Pump V-700 / V-710 Technical data sheet The Vacuum Pump V-700 and V-710 is a chemically resistant PTFE diaphragm pump, de-signed for use with all gases and vapors typically associated with the lab. The pump is opti-mally suited for work with laboratory and industrial rotary evaporators as well as other typical