heating mantle standard operating procedure

OPERATING AND SAFETY INSTRUCTIONS

2015-9-28 · J:\Std User Instructions\PREMIER HEATING MANTLE USER INSTR..doc User Instructions 711 HULMAN STREET PO BOX 2128 TERRE HAUTE, IN 47802 812-235-6167 FAX 812-234-6975 INSTUCTION NOTES FOR THE GLAS-COL PREMIER HEATING MANTLE

Standard Operating Procedures - Coluia University

2007-8-8 · Standard Operating Procedures 1. Standard Operating Procedures OVER VIEW In the following laboratory exercises you will be introduced to some of the glassware and tech - niques used by chemists to isolate components from natural or synthetic mixtures and to purify (you may need to slightly heat for complete dissolution, but make sure the

STANDARD OPERATING PROCEDURES

2016-8-4 · and experienced in autoclave sterilization procedures. 3. Technical staff operating autoclave equipment ensuresthis pro cedure is followed. III. PROCEDURE 1. Autoclave sterilization times and temperatures are dependent on the composition and nature of the items being autoclaved. Minimum times are usually 15 minutes at 250. 0 . F (121. 0

SOP STANDARD OPERATING PROCEDURE - UNE

2017-12-16 · Section 3 – Procedure 1. Know the loion and use of fire extinguishers, fire blankets, and fire exits. 2. Know the emergency evacuation signals and procedure. 3. Assess if a heat gun is a suitable heat source. Heat guns are hand held and for short term <15mins heating appliions only. Do not clamp the heat gun for longer term heating. 4.

Heating Mantle Sop Pdf - diakonie-annaberg.de

Heating Bath SOP 2013 1 Standard Operating Procedure Heat Sources and Heating Baths 1. Procedure/Hazardous Material: Includes, but not limited to ovens, hot plates, heating mantles and tapes, oil baths, salt baths, sand baths, hot-air guns, and microwave ovens. 2. Department: Campus wide 3. Revision Date: February 2013 4. Special Notifiions:

SOP STANDARD OPERATING PROCEDURE - UNE

2017-12-16 · Section 3 – Procedure 1. Know the loion and use of fire extinguishers, fire blankets, and fire exits. 2. Know the emergency evacuation signals and procedure. 3. Assess if a heat gun is a suitable heat source. Heat guns are hand held and for short term <15mins heating appliions only. Do not clamp the heat gun for longer term heating. 4.

STANDARD OPERATING PROCEDURE - CSU

2011-8-10 · heat of the press. °•Pre heat press (154 C) and position mould under plates. Tighten press carefully onto mould and heat for 45 min. •Remove mould from press and allow to cool. •Using a sharp blade cut master free from rubber. Cut anchor points into each corner of mould. Cut evenly around master – this cut should be at the mid point of

SOP STANDARD OPERATING PROCEDURE - UNE

2017-12-16 · Section 3 – Procedure 1. Know the loion and use of fire extinguishers, fire blankets, and fire exits. 2. Know the emergency evacuation signals and procedure. 3. Assess if a heat gun is a suitable heat source. Heat guns are hand held and for short term <15mins heating appliions only. Do not clamp the heat gun for longer term heating. 4.

Standard Operating Procedure

2011-10-4 · 3. The heat pump must be installed on a solid, level mounting pad that will not settle or shift. Separate the pad from the building structure to avoid possible transmission of sound or vibration from the heat pump into the residence. 4. The heat pump foundation should be raised 3 in. or more above finish grade. In areas with prolonged

Standard Operating Procedure - NSF

2017-5-3 · Standard Operating Procedure Updated: May 3, 2017 Page 3 of 18 a. There are two (2) sources of heating the MSF: 1. Latent waste heat from the UPS and Researcher instrumentation that includes computers, chillers, laser heads, heat exchangers, fans, compressors, etc. as part of their data collection suite. Other than encouraging Researcher and

STANDARD OPERATING PROCEDURE - UMD

2015-7-14 · STANDARD OPERATING PROCEDURE Updated: July 14, 2015 . High Temperature Box Furnaces . Procedures for Lindberg Blue High Temperature Furnace s, Small MTK, and Carbolite furnaces . Users are responsible for using the furnaces described according to these procedures. Precautions:

Heat Gun SOP | SafetyDocs PDF & Word Templates

Heat Gun Safe Operating Procedure. This Heat Gun Safe Operating Procedure (SOP) provides a way for your business to outline step-by-step safe processes when using a heat gun. Heat Gun SOP: Provides instructions on the use of the equipment both prior to and during operation. Ensures workers recognise and manage associated hazards and risks involved.

LABORATORY SAFETY MANUAL - University of Washington

LABORATORY SAFETY MANUAL DECEER 2021 EDITION Environmental Health and Safety Department University of Washington Box 354400 Seattle, WA 98195-4400 Phone: 206.543.7262 FAX: 206.543.3351

GLASSCO Heating Mantle

2019-11-5 · General Remarks:-Ø The operator has to make sure that the Heating mantle is stable. Ø Put only Glass flask on the heating mantle that fit the heating mantle''s volume. Ø Always replace the fuse from the same type & current. Ø Always put a Glass flask in the heating mantle. Never put beaker & anything else without flask. Ø Never rotate the Heat knob out of …

Standard Operating Procedure - rtong.people.ust.hk

2017-6-22 · Standard Operating Procedure 3-Chloroperbenzoic acid (MCPBA) This is an SOP template and is not complete until: 1) lab specific information is entered into the box below 2) lab specific protocol/procedure is added to the protocol/procedure section and 3) SOP has been signed and dated by the PI and relevant lab personnel.

STANDARD OPERATING PROCEDURES

2016-8-4 · shown to prevent heat loss better than when a heating blanket is applied to the trunk of anesthetized dogs. e. Only thermostatically controlled water blankets with heat source will be used as a source of intra-operative warmth during procedures involving non-rodent mammals. 5. Use with rodents intra-operatively and immediately post-operatively

Electrical Equipment Safety Procedures

2011-6-22 · stirrer/heater, heat gun, heating mantle, etc • Always follow the example of the Standard Operating Procedure (Appendix 4) applicable to electrical work • Notifying the Office of Facilities Management, Senior Technical Officer Electrical, and / or OFM

1. Procedure/Hazardous Material: 2. Department: 3

2018-2-20 · Heating Bath SOP 2013 1 Standard Operating Procedure Heat Sources and Heating Baths 1. Procedure/Hazardous Material: Includes, but not limited to ovens, hot plates, heating mantles and tapes, oil baths, salt baths, sand baths, hot-air guns, and microwave ovens. 2. Department: Campus wide 3. Revision Date: February 2013 4. Special Notifiions:

The Government s Standard Assessment Procedure for …

2019-10-2 · - the assumed standard heating pattern has been adjusted - provision has been made for heat loss data for heat interface units (for heat networks) to come from the PCDB - the reference building characteristics have been updated SCOPE OF THE SAP PROCEDURE The procedure is applicable to self-contained dwellings (of any size and any age).

How to set up a reflux apparatus

2016-8-13 · The heating mantle should fit the flask size. The temperature will be difficult to control if the heating mantle lacks contact with the flask. The heating mantle will overheat or burn out if left unintended for too long. • Add the sand into the heating mantle. Make sure the sand occupies 2/3 of the heating mantle. Figure 1 Reflux Apparatus

Standard Operating Procedure Emergency Procedures

2020-10-15 · Emergency Procedures SOP-EP-03 Standard Operating Procedure Emergency Procedures SOP Nuer: SOP-EP-03 egory: Administrative Supersedes: SOP-EP-02 Original Date: Deceer 1, 2017 Revised: October 15, 2020 Pages 1 of 34 Issued by: President & CEO, KGHRI 1.0 POLICY

Safe Operating Procedure - University of Nebraska–Lincoln

2020-4-8 · • Heat fainting (heat syncope) is a fainting (syncope) episode or dizziness that usually occurs with prolonged standing or sudden rising from a sitting or lying position. Factors that may contribute to heat syncope include dehydration and lack of acclimatization . If you feel dizzy, seek a cool spot to rest and drink fluids.

Standard Operating Procedure

2021-8-25 · standard operating procedure sop code: can – strl – p3.7.6.0 revision nuer: 2 . 0 . 0 issue date: month 00, yyyy implementation date: month 00, yyyy ☐ controlled copy uncontrolled copy ____ title : procedure – operating – steam heat sterilizer –

Heating | Basic laboratory procedures II

Heating control is provided either by a regulator built into the heating mantle (Fig. 5.13a) or by an external controller, which is connected to the mantle by a plug. Some mantles, ''stirrer mantles'', have a built-in magnetic stirrer just like a …

GLASSCO Heating Mantle

2019-11-5 · General Remarks:-Ø The operator has to make sure that the Heating mantle is stable. Ø Put only Glass flask on the heating mantle that fit the heating mantle''s volume. Ø Always replace the fuse from the same type & current. Ø Always put a Glass flask in the heating mantle. Never put beaker & anything else without flask. Ø Never rotate the Heat knob out of …

37 Best Standard Operating Procedure (SOP) …

37 Best Standard Operating Procedure (SOP) Templates. For organizations or institutions which desire that certain activities are done by following a strict set of steps, the standard operating procedures, SOPs could come in handy for …

Electrical Equipment Safety Procedures

2011-6-22 · stirrer/heater, heat gun, heating mantle, etc • Always follow the example of the Standard Operating Procedure (Appendix 4) applicable to electrical work • Notifying the Office of Facilities Management, Senior Technical Officer Electrical, and / or OFM

Heating Mantles - Facilities Management

2022-4-3 · Heating tapes may also be used to keep distillation columns warm or to regenerate alyst columns. Top of Page. Safety Precautions. Heating mantles should never be plugged directly into an outlet. A heating mantle can easily generate enough heat to vaporize most organic materials and will melt a flask if used on full power.